The fast one-handed tool for mA loop checks in Ex zones - The 707Ex is an intrinsically safe loop calibrator for use in explosion endangered areas. The Fluke 707Ex is certified in accordance with the ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2.
Description

Intrinsically Safe Loop Calibrator - Key Features:

  • Large display and simple, quick-click push rotary button for easy one-handed operation
  • Simultaneous mA and % readout for quick, easy, interpretation of readings.
  • mA accuracy of 0.015%, superior to other loop calibrators
  • 1 µA resolution for mA source, simulate and measure
  • Push button with 25% steps for fast, easy linearity checks
  • 0-100% "span check" for fast confirmation of zero and span
  • Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
  • Internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
  • Measures Vdc to 28 V
  • Single 9 V battery that is easily changed
  • 0-20 mA or 4-20 mA default start up modes
  • Innovative output adjustment dial with 1 µA and 100 µA resolution
  • HART® compatible resistance is connected in series with the loop supply for compatibility with HART communicators

Specifications
Current Measurement
Range:  0 to 24 mA
Resolution:  0.001 mA
Accuracy:  0.015% Rdg + 2 LSD
Current Sourcing
Range:  0 to 20 mA or 4 to 20 mA
Accuracy:  0.015% Rdg + 2 LSD
Drive Capability:  700 Ω at 20 mA
Current Simulation
Range:  0 to 20 mA or 4 to 20 mA
Accuracy:  0.015% Rdg + 2 LSD
Loop Power
 While measuring mA, 24 V
Voltage measurement
Range:  0 to 28 V DC
Resolution:  1 mV
Accuracy:  0.015% Rdg + 2 LSD

Environmental Specifications
Operating Temperature
 -10ºC to 55ºC
Storage Temperature
 -40ºC to 60ºC
Humidity (Without Condensation)
 0 to 95% (0ºC to 30ºC);
 0 to 75% (30ºC to 40ºC)
 0 to 45% (40ºC to 50ºC)
Temperature Coefficient
 -10ºC to 18ºC, 28ºC to 55ºC, ±.005% of range per ºC

Safety Specifications
Safety
 CSA C22.2 No. 1010.1:1992
EMC
 EN50082-1:1992 and EN55022:1994 Class B
Maximum voltage
 30 V
ATEX certification
 Ex II G Ex ia IIC T4 Zones 1 and 2, ZELM 02 ATEX 0120 X
CE certification
 EN61010-1 and EN61326

Mechanical & General Specifications
Size
 152 x 70 x 41 mm
Weight
 224 g (350 g including holster)
Batteries
 One 9V battery Alkaline
Warranty
 3 year
Shock & Vibration
 per MIL-T-28800 for a Class 2 Instrument
Display current and % of span
 Yes
Auto step, auto ramp
 Yes
Span Check
 Yes

Includes:

  • Alligator test clips
  • Instruction manual (on CD-ROM)
  • Protective holster with Flex-Stand™
  • Safety designed test leads
  • NIST- traceable calibration report and data
Datasheet