Yokogawa DM7560 Digital Multimeter
Yokogawa DM7560 Digital Multimeter
Meet the DM7560, a versatile digital multimeter designed for precision. Experience high-accuracy measurements and rapid data logging at up to 30,000 samples per second, complemented by a deep 100,000 reading memory and integrated statistical analysis tools.
The DM7560 stands out for its exceptional stability and reliability, offering 6.5 digits of precision on the benchtop. Even at high sampling rates, it maintains its performance, ensuring accurate measurements in diverse applications. Additionally, its advanced display features provide various formats for intuitive and comprehensive operation, meeting the demands of modern measurement scenarios.
Moreover, the DM7560 enhances productivity with its extensive I/O and communication interfaces, along with advanced analysis functions. Whether for manual or automated testing systems, this multimeter streamlines operations, allowing for efficient data collection and analysis. Its versatility and reliability make it a valuable asset in various industries, contributing to improved productivity and precise measurement outcomes.
Varied Display Formats
Featuring a large 4.3-inch high-resolution display, the DMM7560 offers flexible data observation through a combination of primary and secondary display areas. Icons serve as annunciators, indicating the instrument's status. The primary display area showcases trend charts, histograms, and arc scale meter displays while secondary display area presents options such as analog meter, statistics, and LIMIT judgment displays. Users can customize their display combination, such as trend chart with statistics or numerical value with frequency and analog meter, providing versatile visualizations for efficient data analysis and interpretation.
High-Speed Data Logging
With a maximum 30 kS/s data logging rate, the DM7560 offers efficient bulk mode logging to its internal memory, allowing high sample rates for detailed analysis. Users can transfer logged data to a USB memory device for PC analysis, providing flexibility in data handling and interpretation. Additionally, triggered data logging enables logging to stop based on specified events such as LEVEL, LIMIT, or EXTERNAL TRIGGER, ensuring relevant data capture. The DM7560's high-capacity internal memory of 100 k points allows for long-term, high-resolution data logging, even at high sample rates, enabling continuous measurement for over 27 hours at 1 S/s. This seamless integration with PC-based analysis tools facilitates in-depth data analysis and insights.
Offline Data Analysis
THE DM7560 offers users powerful offline data analysis capabilities directly through the instrument without requiring a linked computer. Users can determine the number of data points, the ratio to whole data percentage, and the yield rate by positioning the cursor on the histogram display and setting upper and lower limit values accordingly. Statistical data such as MAX/MIN/AVG over time can also be calculated automatically, further streamlining the data analysis process. Additionally, users can perform in-depth analyses by zooming into specific regions of the trend chart, enabling a closer examination of voltage distribution and other key metrics. Statistical data, including maximum, minimum, and average values within a cursor-specified range, is automatically calculated, enhancing the analytical capabilities of the DM7560.
For more information regarding pricing and lead times, get in touch at +44 (0) 800 583 4455 or sales@sjelectronics.co.uk
Key Features and Functions
Output rating : 36 W
- Voltage: 60 V
- Current: 0.6 A
- Power: 36 W
Programming accuracy : ± (% of output + offset)
- Voltage: 0.05% + 20 mV
- Current: 0.05% + 0.4 mA
Ripple & noise (20 Hz to 20 MHz)
- Voltage rms: 1.55 mV
- Voltage peak-to-peak: 30 mV
- Current rms: 200 µA
Readback accuracy : ± (% of output + offset)
- Voltage: 0.05% + 12 mV
- Current: 0.05% + 0.3 mA
Keysight E36100B Series basic DC power supplies feature a compact size (2U, ¼-rack), a high-contrast OLED display that is viewable from any angle, and modern USB and LAN (LXI Core) connectivity. Use the highly accurate low-current measure feature for demanding measurements. Protect your DUT with built-in overvoltage and overcurrent protection, and count on the built-in overtemperature protection to keep your power supply safe. Get connected to your instrument quickly via the intuitive front-panel interface, a Web interface running on a browser, a SCPI or IVI program, Keysight IO Libraries, or a BenchVue app running on your PC or mobile device. Choose the best model for your needs: five models offer up to 5 A or 100 V.
Clean, reliable power supply
- Low, normal mode noise specifications assure quality power for precision circuitry applications enabling you to power your design with confidence
- Accurate voltage/current programming and read back capability provides excellent control to precisely power your device under test
- Protection for your device under test (DUT) includes overvoltage, overcurrent, and overtemperature protection
Convenient benchtop capabilities
- USB and LAN (LXI Core)
- BenchVue software support and Web interface control
Compact, intuitive package
- Save space on your bench, 2U ¼ rack
- Easily view the high contrast OLED display
- Intuitive on-screen menu
Sampling Rate
DC functions (DCV, DCI, 2 WΩ, 4 WΩ, TEMP)Power Freq.: 50 Hz Power Freq.: 60 Hz Sampling Rate*1
(S/s)PLC Converted
Value*2Sampling Rate*1
(S/s)PLC
Converted
Value*2Display
DigitRemarks 2.5 (1) 20 2.5 (1) 24 6½ Figures in () are
AUTO ZERO
ON or at 4 WΩ10 (4) 5 10 (4) 6 50 (20) 1 60 (20) 1 100 0.5 100 0.6 5½ This setting
doesn’t exist
at 4 WΩ500 0.1 500 0.12 1 k 0.05 1 k 0.06 2 k 25 m 2 k 0.03 7.5 k 6.67 m 7.5 k 8 m 15 k 3.33 m 15 k 4 m 30 k 1.67 m 30 k 2 m Sampling Rate
AC functions (ACV, ACI)AC Filter Sampling Rate Display
DigitResponse Time*3 Power Freq.: 50 Hz Power Freq.: 60 Hz MID 2.5 S/s (20PLC) 2.5 S/s (24PLC) 6½ Within 3 s HIGH 2.5 S/s (20PLC) 2.5 S/s (24PLC) Within 2 s 10 S/s (5PLC) 10 S/s (6PLC) 50 S/s (1PLC) 60 S/s (1PLC) *1 The sampling rate is guaranteed only when the mode of the Logging function is in the BULK mode.
*2 The PLC converted value corresponds to the sampling cycle/power cycle value.
*3 Time to reach ±100 digits of final value when input changes from 0 to full-scale in the same range.DC Voltage (DCV) - Accuracy
Power Freq.: 50 Hz Power Freq.: 60 Hz Range Full Scale
at 6 ½ DigitsResolution Accuracy
±(% of Reading +
% of Range)Tempco
±(% of Reading +
% of Range)/°CInput
Impedance100 mV 119.9999 0.1 μV 0.0050 + 0.0035 0.0005 + 0.0005 1 GΩ or
more or
10 MΩ ±1%1 V 1.199999 1 μV 0.0040 + 0.0007 0.0005 + 0.0001 10 V 11.99999 10 μV 0.0035 + 0.0005 100 V 119.9999 0.1 mV 0.0045 + 0.0006 10 MΩ ±1% 1000 V 1100.000 1 mV 0.0045 + 0.0010 - Sampling rate: 1 S/s
- Max. allowable voltage
- 100 mV to 100 V range: 800 Vpeak (continuous), 1100 Vpeak (for 1 minute)
- 1000 V range: ±1100 Vpeak (continuous)
Response time: Within 1 s
DC Voltage (DCV) - Noise Rejection
PLC NMRR
50 Hz/60 Hz ±0.1%CMRR
50 Hz/60 Hz ±0.1%
Unbalance resistance 1 kΩMultiple of 1 PLC 55 dB 120 dB Other than above 0 dB — Power Frequency: 50 Hz/60 Hz
AC Voltage (ACV) - Resolution and Measuring Frequency Range
Range Full Scale
at 6 ½ DigitsResolution Measuring Frequency Range Input
ImpedanceMID HIGH 100 mV 119.9999 0.1 μV 20 Hz to 300 kHz 200 Hz to 300 kHz Approx.
1 MΩ//
100 pF
or less1 V 1.199999 1 μV 10 V 11.99999 10 μV 100 V 119.9999 0.1 mV 750 V 750.000 1 mV 20 Hz to 100 kHz 200 Hz to 100 kHz AC Voltage (ACV) - Accuracy
Specified between 5% and 100% of each range.Unit of accuracy: ±(% of reading + % of range)Range Frequency Accuracy Tempco 100 mV 20 Hz to 45 Hz 0.70 + 0.04 0.070 + 0.004 45 Hz to 100 Hz 0.20 + 0.04 0.020 + 0.004 100 Hz to 20 kHz 0.06 + 0.04 0.005 + 0.004 20 kHz to 50 kHz 0.12 + 0.05 0.011 + 0.005 50 kHz to 100 kHz 0.60 + 0.08 0.060 + 0.008 100 kHz to 300 kHz 4.00 + 0.50 0.200 + 0.020 1 V to 750 V 20 Hz to 45 Hz 0.70 + 0.03 0.070 + 0.003 45 Hz to 100 Hz 0.20 + 0.03 0.020 + 0.003 100 Hz to 20 kHz 0.06 + 0.03 0.005 + 0.003 20 kHz to 50 kHz 0.11 + 0.05 0.011 + 0.005 50 kHz to 100 kHz 0.60 + 0.08 0.060 + 0.008 100 kHz to 300 kHz 4.00 + 0.50 0.200 + 0.020 - Sampling rate: 2.5 S/s
- Sine wave input
- Maximum allowable voltage 750 Vrms or 1100 Vpeak and DC content are ±500 V or less.
- Limited to 100 kHz or 8 × 107 [V·Hz] at the 750 V range.
DC Current (DCI) - Accuracy
Range Full Scale
at 6 ½ DigitsResolution Accuracy
±(% of Reading +
% of Range)Tempco
±(% of Reading +
% of Range)/°CInput
Impedance1 mA 1.199999 1 nA 0.050 + 0.006 0.0020 + 0.0050 90 Ω 10 mA 11.99999 10 nA 0.050 + 0.020 0.0020 + 0.0020 5 Ω 100 mA 119.9999 100 nA 0.050 + 0.005 0.0020 + 0.0005 1 A 1.199999 1 μA 0.100 + 0.010 0.0050 + 0.0010 0.1 Ω 3 A 3.00000 10 μA 0.120 + 0.020 0.0050 + 0.0020 - Sampling rate: 1 S/s
- Resolution is specified when the display digit is 6½ digit.
- Maximum allowable current
- Full range: 3 ADC or 3 Arms (continuous, protection by 3 A fuse)
AC Voltage (ACV) - Resolution and Measuring Frequency Range
True RMS, Crest Factor < 5
Range Full Scale Resolution Measuring Frequency Range Input
ImpedanceMID HIGH 1 A 1.199999 1 μA 20 Hz to 5 kHz 200 Hz to 5 kHz 0.1 Ω 3 A 3.00000 10 μA AC Current (ACI) - Accuracy
Specified between 5% and 100% of each range.Unit of accuracy: ±(% of reading + % of range)Range Frequency Accuracy Tempco 1 A 20 Hz to 45 Hz 0.70 + 0.04 0.100 + 0.006 45 Hz to 100 Hz 0.30 + 0.04 0.035 + 0.006 100 Hz to 5 kHz 0.10 + 0.04 0.015 + 0.006 3 A 20 Hz to 45 Hz 0.70 + 0.06 0.100 + 0.006 45 Hz to 100 Hz 0.35 + 0.06 0.035 + 0.006 100 Hz to 5 kHz 0.15 + 0.06 0.015 + 0.006 - Sampling rate: 2.5 S/s
- Sine wave input
- Maximum allowable currentFull range: 3 Arms (Continuous, protection by 3 A fuse)
- Sampling rate: 1 S/s