FLIR Si2-Pro Industrial Acoustic Imaging Camera
FLIR Si2-Pro Industrial Acoustic Imaging Camera
The FLIR Si2-Pro Industrial Acoustic Imaging Camera is your go-to solution for detecting mechanical faults early, saving you from costly downtime caused by bearing issues. It also helps you prioritize repairs by accurately quantifying leak rates, reducing expenses associated with gas and air leaks. With features like on-camera severity assessment and fleet management functionality, this camera ensures swift and accurate diagnosis while optimizing tool usage across your operations. Perfect for routine inspections and preventative maintenance in various industrial settings, it helps you stay compliant with safety standards and manage operational costs effectively.
Advanced Leak Detection
Achieve unparalleled precision in detecting, locating, and measuring compressed air leaks, gas leaks, and partial discharges with the FLIR Si2-Pro Industrial Acoustic Imaging Camera. This advanced technology empowers you to identify and quantify even the most minor and elusive issues from distances of up to 200 meters, ensuring thorough coverage of your industrial environment. By boosting operational efficiency and maintaining safety standards, the FLIR Si2-Pro is an indispensable tool for any facility or operation.
Bearing Fault Analysis
Cut down on expensive repairs, minimize downtime, and optimize maintenance efficiency by preemptively identifying bearing defects before they lead to equipment failures. This proactive approach not only saves on repair costs but also ensures uninterrupted operations and extends the lifespan of your equipment. By addressing potential issues before they escalate, you can maintain smooth and efficient operations while avoiding costly disruptions.
Fleet Management Functionality
Maximize the utilization and upkeep of equipment in expansive industrial environments by implementing comprehensive fleet management strategies, integrating cloud-based data solutions, and implementing over-the-air (OTA) software updates. Seamlessly merging acoustic and thermal imaging within a single report enhances diagnostic capabilities, enables more informed decision-making and proactive maintenance practices. This integrated approach not only streamlines operations but also improves equipment performance and longevity, ensuring optimal productivity and minimizing downtime.
For more information regarding pricing and lead times, get in touch at +44 (0) 800 583 4455 or sales@sjelectronics.co.uk
Key Features and Functions
Output rating : 36 W
- Voltage: 60 V
- Current: 0.6 A
- Power: 36 W
Programming accuracy : ± (% of output + offset)
- Voltage: 0.05% + 20 mV
- Current: 0.05% + 0.4 mA
Ripple & noise (20 Hz to 20 MHz)
- Voltage rms: 1.55 mV
- Voltage peak-to-peak: 30 mV
- Current rms: 200 µA
Readback accuracy : ± (% of output + offset)
- Voltage: 0.05% + 12 mV
- Current: 0.05% + 0.3 mA
Keysight E36100B Series basic DC power supplies feature a compact size (2U, ¼-rack), a high-contrast OLED display that is viewable from any angle, and modern USB and LAN (LXI Core) connectivity. Use the highly accurate low-current measure feature for demanding measurements. Protect your DUT with built-in overvoltage and overcurrent protection, and count on the built-in overtemperature protection to keep your power supply safe. Get connected to your instrument quickly via the intuitive front-panel interface, a Web interface running on a browser, a SCPI or IVI program, Keysight IO Libraries, or a BenchVue app running on your PC or mobile device. Choose the best model for your needs: five models offer up to 5 A or 100 V.
Clean, reliable power supply
- Low, normal mode noise specifications assure quality power for precision circuitry applications enabling you to power your design with confidence
- Accurate voltage/current programming and read back capability provides excellent control to precisely power your device under test
- Protection for your device under test (DUT) includes overvoltage, overcurrent, and overtemperature protection
Convenient benchtop capabilities
- USB and LAN (LXI Core)
- BenchVue software support and Web interface control
Compact, intuitive package
- Save space on your bench, 2U ¼ rack
- Easily view the high contrast OLED display
- Intuitive on-screen menu
-
Acoustic Measurement
Detection Threshold 20 kHz: -7 dB SPL
35 kHz: 4 dB SPL
50 kHz: 10 dB SPL
80 kHz: 36 dB SPL
100 kHz: 51 dB SPLBandwidth 2 kHz -130 kHz Directional Resolution From 1° up to 0.125° Operating Distance From 0.3 m (1.0 ft) up to 200 m (656 ft) Severity Assessment Automatic AI-based severity assessment including recommended actions onboard camera Leak Localisation and Detection Automatic leak recognition including estimated leak size and annual cost Leak Rate Detection Threshold 0.0032 l/min from 2.5 m, 0.0044 l/min from 6 m Supported Gases Compressed air, hydrogen, CO2, methane, natural gas, helium, argon, ammonia Other Acoustic Analysis Modes Mechanical fault detection Imaging & Optical
Digital Camera 12 MP colour Camera Field of View 75° diagonal Video Frame Rate Camera: 60 fps / Acoustic image: 30 fps / Screen: 70 fps Zoom 8x Digital Zoom Video Image Resolution 1280 x 720 User Interface
Display Size: 5 in. 1280 x 720Resistive touch screen, TFT LCD, MIPI DSIIntegrated Flashlight LEDs, two modes: ON/OFF Analysis and Reporting
Online FLIR Acoustic Camera Viewer (cloud service)Offline FLIR Thermal Studio (desktop software) Communication and Data Storage
Data Transfer Wi-Fi 2.4 GHz and 5 GHz IEEE 802.11.b/g/n/ac wireless LAN USB memory stickCamera Software Update Automatic Over The Air (OTA) wireless update or via USB connection Still Image Format .nlz and .jpg Video Recording & Format Up to 5 minutes (.nlz format) Storage, Internal 128 GB (SD card) Storage, External USB 8 GB, Cloud storage capacity is unlimited Image Annotations Image tags and comments Power Supply
Camera Power Input Nominal input voltage: 12 V DC
Max input: 17 V DC , 3.3 A (limited)Battery Li-Ion rechargeable battery pack (RRC 2054):14.4 V DC, 3.45 Ah, 49.68 Wh
Usage: Up to 2.5 h (depends on ambient conditions & usage,
needs to be retested and confirmed with final product)
Charge time: approx. 2 h
Max output: 16.8 V DC, 5 ABattery Charger Input: 19-26 V DC, 2.8 A
Max output: 17.4 V DC, 4.8 AEnvironmental Data
Operating Temperature Range -10°C to 50°C (14°F to 122°F)Storage Temperature Range -20°C to 50°C max -20°C to 25°C recommended
(determined by the battery)Relative Humidity 0-90% recommended EMC CFR47 FCC Part 15 Subpart B Radio CFR47 FCC Part 15 Subpart C/E, ETSI EN 301 489-1/-17, ETSI EN 300 328, ETSI EN 301 893 Ingress Protection IP54 Safety IEC 62368-1 Declaration of Conformity See: https://support.flir.com/resources/DoC Physical Data
Camera Size 288 mm × 182 mm × 159 mm (11 in × 7 in × 6 in)Camera Weight ~ 1.2 kg Battery Size 85 mm × 77 mm (RRC2504) Battery Weight ~ 0.25 kg Total Weight (Camera + Battery) ~ 1.45 kg