Fluke Calibration 1504 1 Channel Thermometer Readout
1 Channel Thermometer for Thermistors
Best performance thermometers in their price range
- Two Tweeners to choose from—reading PRTs or thermistors
- Battery packs available
- Best price/performance package
One of Hart’s best-selling products is the Tweener thermometer, and there’s a reason. No other company, not one, has a reference thermometer that comes close to the performance and features of the Tweener for anywhere near its price.
1504 Tweener Thermistor Readout
If you need more accuracy in a limited temperature range, the Model 1504 Tweener gives it to you as a thermistor readout. Thermistors are less fragile than PRTs and less likely to be impacted by mechanical shock. Thermistors are more sensitive to temperature, have faster response times, and come in many shapes for different applications.
Typical accuracy of 1504 is ±0.002 °C with a resolution of 0.0001 °C.
Software
With our 9934 LogWare, both Tweener models may be used for real-time data acquisition. Collect data and analyze it graphically or statistically. Additionally, Tweeners may be used as reference thermometers with our MET/TEMP II software.
Battery pack
Want to take your Tweener on the road? Order Hart’s 9320A Battery Pack. Our battery gives you 36 hours between charges, allowing you to take your work wherever you need.
Calibration choices
Each Tweener and its accompanying probe (sold separately) have their own individual calibration reports. Overall system error can be calculated from the individual errors, rendering the added cost of system data unnecessary. However, for those requiring it, system data is available at two or more temperatures of your choice. (See Calibration Model 1929-X )
Specifications |
1502A | 1504 |
Temperature Range† | −200 °C to 962 °C (−328 °F to 1764 °F) | Any thermistor range |
Resistance Range | 0W to 400W, auto-ranging | 0W to 1 MW, auto-ranging |
Probe | Nominal RTPW: 10W to 100W RTD, PRT, or SPRT |
Thermistors |
Characterizations | ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 IPTS-68: R0, a, d, a4, and c4 Callendar-Van Dusen: R0, a, d, and b |
Steinhart-Hart thermistor polynomial Callendar-Van Dusen: R0, a, d, and b |
Resistance Accuracy (ppm of reading) |
0W to 20W: 0.0005W 20W to 400W: 25 ppm |
0W to 5 KW: 0.5W 5 KW to 200 KW: 100 ppm 200 KW to 1 MW: 300 ppm |
Temperature Accuracy† | ±0.004 °C at −100 °C ±0.006 °C at 0 °C ±0.009 °C at 100 °C ±0.012 °C at 200 °C ±0.018 °C at 400 °C ±0.024 °C at 600 °C |
±0.002 °C at 0 °C ±0.002 °C at 25 °C ±0.004 °C at 50 °C ±0.010 °C at 75 °C ±0.020 °C at 100 °C (Using 10 KW thermistor sensor, a=0.04. Does not include probe uncertainty or characterization errors.) |
Operating Temperature Range | 16 °C to 30 °C | 13 °C to 33 °C |
Resistance Resolution | 0W to 20W: 0.0001W 20W to 400W: 0.001W |
0W to 10 KW: 0.01W 10 KW to 100 KW: 0.1W 100 KW to 1 MW: 1W |
Temperature Resolution | 0.001 °C | 0.0001 °C |
Excitation Current | 0.5 and 1 mA, user selectable, 2 Hz | 2 and 10 mA, automatically selected |
Measurement Period | 1 second | |
Digital Filter | Exponential, 0 to 60 seconds time constant (user selectable) | |
Probe Connection | 4-wire with shield, 5-pin DIN connector | |
Communications | RS-232 serial standard IEEE-488 (GPIB) optional |
|
Display | 8-digit, 7-segment, yellow-green LED; 0.5-inch-high characters | |
Power | 115 VAC (±10 %), 50/60 Hz, 1 A, nominal 230 VAC (±10 %), 50/60 Hz, 1 A, nominal, specify |
|
Size (HxWxD) | 61 x 143 x 181mm (2.4 x 5.6 x 7.1 in) | |
Weight | 1.0 kg (2.2 lb.) | |
Probes from Hart | 5615, 5627, 5626, 5628, 5622 | 5640-44, 5610-65 |
Calibration | ISO 17025-accredited calibration provided | |
†Temperature ranges and accuracy may be limited by the sensor you use. |