Fluke Calibration 9144-A-P-256 Field Metrology Well
Field Metrology Well, 50 degC - 660 degC, with Insert 9144-INSA and Built-In Process Electronics, 220 V / 50/60 Hz
Field Metrology Well, 50 degC - 660 degC, with Insert 9144-INSA and Built-In Process Electronics, 220 V / 50/60 Hz
Small dry wells for big field applications
The 914X Series Field Metrology Wells (Fluke 9142, Fluke 9143, Fluke 9144) extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (Fluke 9142, Fluke 9143, and Fluke 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C.
High performance for the industrial environment
Field Metrology Wells are designed for the industrial process environment. They weigh less than 8.2 kg (18 lb) and have a small footprint, which makes them easy to transport. Optimized for speed, Field Metrology Wells cool to –25 °C in 15 minutes and heat to 660 °C in 15 minutes.
Field environment conditions are typically unstable, having wide temperature variations. Each Field Metrology Well has a built-in gradient-temperature compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed over the environmental range of 13 °C to 33 °C.
- Lightweight, portable, and fast
- Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutes
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
-
Best Practices for Temperature Calibration >
Comparison calibration made easy with a 914X Series Field Metrology Well >
Eliminating Sensor Errors in Loop Calibrations >
How to Calibrate an RTD or Platinum Resistance Thermometer (PRT) >
Improving Loop Calibration Temperature Accuracy >
Process Calibration Tools: Temperature Applications >
Selecting an Industrial Temperature Calibrator >
Temperature Calibration Equipment: A Technician's Guide >
Temperature measurement and calibration: What every instrument technician should know >